{"id":621,"date":"2025-07-22T06:25:52","date_gmt":"2025-07-22T06:25:52","guid":{"rendered":"https:\/\/www.purunspaceframe.com\/?post_type=product&#038;p=621"},"modified":"2025-10-08T01:03:13","modified_gmt":"2025-10-08T01:03:13","slug":"steel-structure-construction-warehouse-installation-completed","status":"publish","type":"product","link":"https:\/\/www.purunspaceframe.com\/cn\/product\/steel-structure-construction-warehouse-installation-completed\/","title":{"rendered":"\u00a0Steel Structure Construction Warehouse Installation Completed"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"<p>The core of steel structure plant installation is &#8220;precision control + safety assurance&#8221;: reduce hidden dangers through drawing review and component inspection in the early stage, ensure quality through standardized lifting and connection processes during installation, and take safety and acceptance standards as the bottom line throughout the process. Special attention should be paid to the safety of high-altitude operations, the reliability of bolt\/welding connections, and subsequent anti-corrosion treatment (which directly affects the service life of the plant). Following the above points can effectively reduce the rework rate and ensure the safety and stability of the plant structure.<\/p>\n","protected":false},"featured_media":953,"template":"","meta":{"inline_featured_image":false},"products":[6,16,17],"class_list":["post-621","product","type-product","status-publish","has-post-thumbnail","hentry","products-steel-structure","products-steel-structure-processing","products-steel-structure-installation"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.3.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>\u00a0Steel Structure Construction Warehouse Installation Completed - PURUN Steel Structure<\/title>\n<meta name=\"description\" content=\"Drawings and technical briefing Before construction, the design drawings (including structural layout drawings, node details, component size tables, etc.) must be checked to confirm that the component model, quantity, and connection method are consistent with the on-site requirements.Organize technical briefing: The design party, supervision party, and construction party jointly participate in clarifying the installation requirements of key nodes (such as beam-column connections and roof support nodes), and marking easy-to-error points (such as bolt hole alignment and welding groove angle).Component on-site inspection and storage Component acceptance: Check the dimensional deviation (such as length, verticality, curvature), surface flatness, and bolt hole position and embedded parts of components such as steel columns, steel beams, and purlins (the deviation must comply with the requirements of &quot;Standards for Quality Acceptance of Steel Structure Engineering Construction&quot; GB50205).Storage specifications: Components must be stacked in accordance with the installation order, and the bottom must be raised with wooden blocks (to avoid rust on the ground due to moisture). Slender components (such as purlins and supports) must be equipped with support points to prevent deformation; high-strength bolts, welding rods and other accessories must be stored separately in a dry environment to avoid moisture affecting performance.Foundation and site preparation Foundation review: Check the axis position, elevation, position and verticality of embedded bolts (or embedded parts) of the concrete foundation. If the deviation exceeds the allowable range (such as bolt displacement &gt; 10mm), it is necessary to deal with it in advance (such as hole expansion and rebar planting) to avoid the components being unable to be installed.Site planning: Divide the component stacking area, processing area (such as on-site cutting and drilling), and hoisting operation area to ensure that the hoisting route is unobstructed; the ground needs to be flat and hardened to prevent the crane legs from sinking and causing overturning.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.purunspaceframe.com\/cn\/product\/steel-structure-construction-warehouse-installation-completed\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u00a0Steel Structure Construction Warehouse Installation Completed - PURUN Steel Structure\" \/>\n<meta property=\"og:description\" content=\"Drawings and technical briefing Before construction, the design drawings (including structural layout drawings, node details, component size tables, etc.) must be checked to confirm that the component model, quantity, and connection method are consistent with the on-site requirements.Organize technical briefing: The design party, supervision party, and construction party jointly participate in clarifying the installation requirements of key nodes (such as beam-column connections and roof support nodes), and marking easy-to-error points (such as bolt hole alignment and welding groove angle).Component on-site inspection and storage Component acceptance: Check the dimensional deviation (such as length, verticality, curvature), surface flatness, and bolt hole position and embedded parts of components such as steel columns, steel beams, and purlins (the deviation must comply with the requirements of &quot;Standards for Quality Acceptance of Steel Structure Engineering Construction&quot; GB50205).Storage specifications: Components must be stacked in accordance with the installation order, and the bottom must be raised with wooden blocks (to avoid rust on the ground due to moisture). Slender components (such as purlins and supports) must be equipped with support points to prevent deformation; high-strength bolts, welding rods and other accessories must be stored separately in a dry environment to avoid moisture affecting performance.Foundation and site preparation Foundation review: Check the axis position, elevation, position and verticality of embedded bolts (or embedded parts) of the concrete foundation. If the deviation exceeds the allowable range (such as bolt displacement &gt; 10mm), it is necessary to deal with it in advance (such as hole expansion and rebar planting) to avoid the components being unable to be installed.Site planning: Divide the component stacking area, processing area (such as on-site cutting and drilling), and hoisting operation area to ensure that the hoisting route is unobstructed; the ground needs to be flat and hardened to prevent the crane legs from sinking and causing overturning.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.purunspaceframe.com\/cn\/product\/steel-structure-construction-warehouse-installation-completed\/\" \/>\n<meta property=\"og:site_name\" content=\"PURUN Steel Structure\" \/>\n<meta property=\"article:modified_time\" content=\"2025-10-08T01:03:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.purunspaceframe.com\/wp-content\/uploads\/2025\/07\/Steel-Structure-Construction-Warehouse-Installation-Completed-1-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"576\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.purunspaceframe.com\/product\/steel-structure-construction-warehouse-installation-completed\/\",\"url\":\"https:\/\/www.purunspaceframe.com\/product\/steel-structure-construction-warehouse-installation-completed\/\",\"name\":\"\u00a0Steel Structure Construction Warehouse Installation Completed - PURUN Steel Structure\",\"isPartOf\":{\"@id\":\"https:\/\/www.purunspaceframe.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.purunspaceframe.com\/product\/steel-structure-construction-warehouse-installation-completed\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.purunspaceframe.com\/product\/steel-structure-construction-warehouse-installation-completed\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.purunspaceframe.com\/wp-content\/uploads\/2025\/07\/Steel-Structure-Construction-Warehouse-Installation-Completed-1-1.jpg\",\"datePublished\":\"2025-07-22T06:25:52+00:00\",\"dateModified\":\"2025-10-08T01:03:13+00:00\",\"description\":\"Drawings and technical briefing Before construction, the design drawings (including structural layout drawings, node details, component size tables, etc.) must be checked to confirm that the component model, quantity, and connection method are consistent with the on-site requirements.Organize technical briefing: The design party, supervision party, and construction party jointly participate in clarifying the installation requirements of key nodes (such as beam-column connections and roof support nodes), and marking easy-to-error points (such as bolt hole alignment and welding groove angle).Component on-site inspection and storage Component acceptance: Check the dimensional deviation (such as length, verticality, curvature), surface flatness, and bolt hole position and embedded parts of components such as steel columns, steel beams, and purlins (the deviation must comply with the requirements of \\\"Standards for Quality Acceptance of Steel Structure Engineering Construction\\\" GB50205).Storage specifications: Components must be stacked in accordance with the installation order, and the bottom must be raised with wooden blocks (to avoid rust on the ground due to moisture). Slender components (such as purlins and supports) must be equipped with support points to prevent deformation; high-strength bolts, welding rods and other accessories must be stored separately in a dry environment to avoid moisture affecting performance.Foundation and site preparation Foundation review: Check the axis position, elevation, position and verticality of embedded bolts (or embedded parts) of the concrete foundation. If the deviation exceeds the allowable range (such as bolt displacement > 10mm), it is necessary to deal with it in advance (such as hole expansion and rebar planting) to avoid the components being unable to be installed.Site planning: Divide the component stacking area, processing area (such as on-site cutting and drilling), and hoisting operation area to ensure that the hoisting route is unobstructed; the ground needs to be flat and hardened to prevent the crane legs from sinking and causing overturning.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.purunspaceframe.com\/product\/steel-structure-construction-warehouse-installation-completed\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.purunspaceframe.com\/product\/steel-structure-construction-warehouse-installation-completed\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.purunspaceframe.com\/product\/steel-structure-construction-warehouse-installation-completed\/#primaryimage\",\"url\":\"https:\/\/www.purunspaceframe.com\/wp-content\/uploads\/2025\/07\/Steel-Structure-Construction-Warehouse-Installation-Completed-1-1.jpg\",\"contentUrl\":\"https:\/\/www.purunspaceframe.com\/wp-content\/uploads\/2025\/07\/Steel-Structure-Construction-Warehouse-Installation-Completed-1-1.jpg\",\"width\":1024,\"height\":576,\"caption\":\"Steel Structure Construction Warehouse Installation Completed 1\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.purunspaceframe.com\/product\/steel-structure-construction-warehouse-installation-completed\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.purunspaceframe.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/www.purunspaceframe.com\/product\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"\u00a0Steel Structure Construction Warehouse Installation Completed\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.purunspaceframe.com\/#website\",\"url\":\"https:\/\/www.purunspaceframe.com\/\",\"name\":\"PURUN Steel Structure\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.purunspaceframe.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u00a0Steel Structure Construction Warehouse Installation Completed - PURUN Steel Structure","description":"Drawings and technical briefing Before construction, the design drawings (including structural layout drawings, node details, component size tables, etc.) must be checked to confirm that the component model, quantity, and connection method are consistent with the on-site requirements.Organize technical briefing: The design party, supervision party, and construction party jointly participate in clarifying the installation requirements of key nodes (such as beam-column connections and roof support nodes), and marking easy-to-error points (such as bolt hole alignment and welding groove angle).Component on-site inspection and storage Component acceptance: Check the dimensional deviation (such as length, verticality, curvature), surface flatness, and bolt hole position and embedded parts of components such as steel columns, steel beams, and purlins (the deviation must comply with the requirements of \"Standards for Quality Acceptance of Steel Structure Engineering Construction\" GB50205).Storage specifications: Components must be stacked in accordance with the installation order, and the bottom must be raised with wooden blocks (to avoid rust on the ground due to moisture). Slender components (such as purlins and supports) must be equipped with support points to prevent deformation; high-strength bolts, welding rods and other accessories must be stored separately in a dry environment to avoid moisture affecting performance.Foundation and site preparation Foundation review: Check the axis position, elevation, position and verticality of embedded bolts (or embedded parts) of the concrete foundation. If the deviation exceeds the allowable range (such as bolt displacement > 10mm), it is necessary to deal with it in advance (such as hole expansion and rebar planting) to avoid the components being unable to be installed.Site planning: Divide the component stacking area, processing area (such as on-site cutting and drilling), and hoisting operation area to ensure that the hoisting route is unobstructed; the ground needs to be flat and hardened to prevent the crane legs from sinking and causing overturning.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.purunspaceframe.com\/cn\/product\/steel-structure-construction-warehouse-installation-completed\/","og_locale":"en_US","og_type":"article","og_title":"\u00a0Steel Structure Construction Warehouse Installation Completed - PURUN Steel Structure","og_description":"Drawings and technical briefing Before construction, the design drawings (including structural layout drawings, node details, component size tables, etc.) must be checked to confirm that the component model, quantity, and connection method are consistent with the on-site requirements.Organize technical briefing: The design party, supervision party, and construction party jointly participate in clarifying the installation requirements of key nodes (such as beam-column connections and roof support nodes), and marking easy-to-error points (such as bolt hole alignment and welding groove angle).Component on-site inspection and storage Component acceptance: Check the dimensional deviation (such as length, verticality, curvature), surface flatness, and bolt hole position and embedded parts of components such as steel columns, steel beams, and purlins (the deviation must comply with the requirements of \"Standards for Quality Acceptance of Steel Structure Engineering Construction\" GB50205).Storage specifications: Components must be stacked in accordance with the installation order, and the bottom must be raised with wooden blocks (to avoid rust on the ground due to moisture). Slender components (such as purlins and supports) must be equipped with support points to prevent deformation; high-strength bolts, welding rods and other accessories must be stored separately in a dry environment to avoid moisture affecting performance.Foundation and site preparation Foundation review: Check the axis position, elevation, position and verticality of embedded bolts (or embedded parts) of the concrete foundation. If the deviation exceeds the allowable range (such as bolt displacement > 10mm), it is necessary to deal with it in advance (such as hole expansion and rebar planting) to avoid the components being unable to be installed.Site planning: Divide the component stacking area, processing area (such as on-site cutting and drilling), and hoisting operation area to ensure that the hoisting route is unobstructed; the ground needs to be flat and hardened to prevent the crane legs from sinking and causing overturning.","og_url":"https:\/\/www.purunspaceframe.com\/cn\/product\/steel-structure-construction-warehouse-installation-completed\/","og_site_name":"PURUN Steel Structure","article_modified_time":"2025-10-08T01:03:13+00:00","og_image":[{"width":1024,"height":576,"url":"https:\/\/www.purunspaceframe.com\/wp-content\/uploads\/2025\/07\/Steel-Structure-Construction-Warehouse-Installation-Completed-1-1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.purunspaceframe.com\/product\/steel-structure-construction-warehouse-installation-completed\/","url":"https:\/\/www.purunspaceframe.com\/product\/steel-structure-construction-warehouse-installation-completed\/","name":"\u00a0Steel Structure Construction Warehouse Installation Completed - PURUN Steel Structure","isPartOf":{"@id":"https:\/\/www.purunspaceframe.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.purunspaceframe.com\/product\/steel-structure-construction-warehouse-installation-completed\/#primaryimage"},"image":{"@id":"https:\/\/www.purunspaceframe.com\/product\/steel-structure-construction-warehouse-installation-completed\/#primaryimage"},"thumbnailUrl":"https:\/\/www.purunspaceframe.com\/wp-content\/uploads\/2025\/07\/Steel-Structure-Construction-Warehouse-Installation-Completed-1-1.jpg","datePublished":"2025-07-22T06:25:52+00:00","dateModified":"2025-10-08T01:03:13+00:00","description":"Drawings and technical briefing Before construction, the design drawings (including structural layout drawings, node details, component size tables, etc.) must be checked to confirm that the component model, quantity, and connection method are consistent with the on-site requirements.Organize technical briefing: The design party, supervision party, and construction party jointly participate in clarifying the installation requirements of key nodes (such as beam-column connections and roof support nodes), and marking easy-to-error points (such as bolt hole alignment and welding groove angle).Component on-site inspection and storage Component acceptance: Check the dimensional deviation (such as length, verticality, curvature), surface flatness, and bolt hole position and embedded parts of components such as steel columns, steel beams, and purlins (the deviation must comply with the requirements of \"Standards for Quality Acceptance of Steel Structure Engineering Construction\" GB50205).Storage specifications: Components must be stacked in accordance with the installation order, and the bottom must be raised with wooden blocks (to avoid rust on the ground due to moisture). Slender components (such as purlins and supports) must be equipped with support points to prevent deformation; high-strength bolts, welding rods and other accessories must be stored separately in a dry environment to avoid moisture affecting performance.Foundation and site preparation Foundation review: Check the axis position, elevation, position and verticality of embedded bolts (or embedded parts) of the concrete foundation. If the deviation exceeds the allowable range (such as bolt displacement > 10mm), it is necessary to deal with it in advance (such as hole expansion and rebar planting) to avoid the components being unable to be installed.Site planning: Divide the component stacking area, processing area (such as on-site cutting and drilling), and hoisting operation area to ensure that the hoisting route is unobstructed; the ground needs to be flat and hardened to prevent the crane legs from sinking and causing overturning.","breadcrumb":{"@id":"https:\/\/www.purunspaceframe.com\/product\/steel-structure-construction-warehouse-installation-completed\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.purunspaceframe.com\/product\/steel-structure-construction-warehouse-installation-completed\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.purunspaceframe.com\/product\/steel-structure-construction-warehouse-installation-completed\/#primaryimage","url":"https:\/\/www.purunspaceframe.com\/wp-content\/uploads\/2025\/07\/Steel-Structure-Construction-Warehouse-Installation-Completed-1-1.jpg","contentUrl":"https:\/\/www.purunspaceframe.com\/wp-content\/uploads\/2025\/07\/Steel-Structure-Construction-Warehouse-Installation-Completed-1-1.jpg","width":1024,"height":576,"caption":"Steel Structure Construction Warehouse Installation Completed 1"},{"@type":"BreadcrumbList","@id":"https:\/\/www.purunspaceframe.com\/product\/steel-structure-construction-warehouse-installation-completed\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.purunspaceframe.com\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.purunspaceframe.com\/product\/"},{"@type":"ListItem","position":3,"name":"\u00a0Steel Structure Construction Warehouse Installation Completed"}]},{"@type":"WebSite","@id":"https:\/\/www.purunspaceframe.com\/#website","url":"https:\/\/www.purunspaceframe.com\/","name":"PURUN Steel Structure","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.purunspaceframe.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.purunspaceframe.com\/cn\/wp-json\/wp\/v2\/product\/621","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.purunspaceframe.com\/cn\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.purunspaceframe.com\/cn\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.purunspaceframe.com\/cn\/wp-json\/wp\/v2\/media\/953"}],"wp:attachment":[{"href":"https:\/\/www.purunspaceframe.com\/cn\/wp-json\/wp\/v2\/media?parent=621"}],"wp:term":[{"taxonomy":"products","embeddable":true,"href":"https:\/\/www.purunspaceframe.com\/cn\/wp-json\/wp\/v2\/products?post=621"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}